Modbus Bridge
Firmware
Downloads:
current release | |
previous release | |
app-modbus-lora-bridge-0.3.1.hex | latest release with old stack version |
Changelog
app-modbus-lora-
bridge
–
Reading
modbus
devices
remotely
over
LoRaWAN.
This
changelog's
format
is
based
on
[ ](https://keepachangelog.com/en/1.0.0/), and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0.html). ###, and this project adheres to Semantic Versioning.
1.3.0
-
2020-12-16
WARNING:
this
version
has
some
changes
that
could
break
your
integration
if
you
have
a
very
specific
parser!
An
undocumented
Payload
Format
has
been
removed
and
the
Status
Message
(Port
1)
is
2
bytes
longer.
#### Changed - Replace broken compact payload formats (2 and 3) with new version (4 and 5). #### Added - Feedback by LED blinking patterns for success/failure reading data and otaa join. - Add Reboot Reason and Final Words to status message. - Add Config Parameter `PowerDelay` to control warm up time of sensors that are powered by the bridge. #### Fixed - Increase stack size for dialog mode. ### 1.2.2 - 2020-06-18 #### Changed - Using Lobawan 1.2.2 (fixes some issues with OTAA Joins). ### 1.2.1 - 2020-02-17 #### Added - Display Version of Lobaro LoRaWAN Stack on boot. #### Fixed - Fix a crash when using remote command `append`. ### 1.2.0 #### Added - New config parameter `MbAttempts` to control how often Modbus Commands will be repeated in case of timeouts. ### 1.1.1 #### Changed - Increased size available for config. ### 1.1.0 #### Added - New optional Listen-Before-Talk Modbus communication, so device can coordinate with another master on bus. #### Fixed - Fix issue that could cut of long Modbus responses. ### 1.0.3 #### Changed - Dialog Mode now logs activity on RS485 Bus while not communicating (to detect other Modbus Masters). - Log Frequencies for LoRaWAN. ### 1.0.2 #### Added - Wait cycles for optional capacitors to load and stabilize on startup ### 1.0.1 #### Changed - Using FRAM for storing results before uploading, allowing for multiple kB of data to be sent (size depending on hardware). #### Fixed - Removed memory corruption error that could be triggered by configurations with lots of Modbus commands. ### 1.0.0 #### Added - LoRaWAN 1.1 support - Remote configuration via LoRaWAN on port 128. - Clock synchronisation via LoRaWAN. #### Changed - Random delay before Uplink (to prevent persistent collisions when using multiple devices). - Modbus responses longer than payload now get split up (additional parts on port 5). ### 0.4.1 #### Fixed - Changed error indication bit on error 11 from `0xf0` to `0x80`. - Fixed issue when parsing multiple Modbus commands from config. ### 0.4.0 #### Added - Writing values to holding registers and coils. - Execution of arbitrary Modbus commands triggered by LoRaWAN Downlink messages. - Support for LoRaWAN Operation Mode Class C (for short reaction time to Downlinks). - Automated register writing and broadcasts possible through new configuration. #### Changed - Automated reading (triggered by cron) is now configured by entering actual Modbus commands (more flexibility and usage of already existing Modbus syntax – *this breaks old configurations*). - Upload format changed to sending raw response to Modbus commands (*this breaks existing integrations*). #### Fixed - Flushing to avoid invalid byte received from switching from TX to RX. - Modbus mode ASCII now counts received bytes correctly. - DataLength of 7 bits can now correctly be set in config again. ### 0.3.1 - 2019-05-24 #### Fixed - Increased robustness of data reception on higher Baud rates. ### 0.3.0 - 2019-05-15 #### Added - Initial release of Firmware for new Hardware revision (with RS485-addon). - Update Modbus to support all 4 types of registers. #### Changed - Parity bit must not be subtracted from Data bits anymore. `8E1` can now be configured with `8 Data bits, EVEN parity, 1 Stop bit`. ### 0.1.0 – 2018-08-13 #### Added - Original hardware release (with RS-485 on holding PCB).Changed
- Replace broken compact payload formats (2 and 3) with new version (4 and 5).
Added
- Feedback by LED blinking patterns for success/failure reading data and otaa join.
- Add Reboot Reason and Final Words to status message.
- Add Config Parameter
PowerDelay
to control warm up time of sensors that are powered by the bridge.
Fixed
- Increase stack size for dialog mode.
1.2.2 - 2020-06-18
Changed
- Using Lobawan 1.2.2 (fixes some issues with OTAA Joins).
1.2.1 - 2020-02-17
Added
- Display Version of Lobaro LoRaWAN Stack on boot.
Fixed
- Fix a crash when using remote command
append
.
1.2.0
Added
- New config parameter
MbAttempts
to control how often Modbus Commands will be repeated in case of timeouts.
1.1.1
Changed
- Increased size available for config.
1.1.0
Added
- New optional Listen-Before-Talk Modbus communication, so device can coordinate with another master on bus.
Fixed
- Fix issue that could cut of long Modbus responses.
1.0.3
Changed
- Dialog Mode now logs activity on RS485 Bus while not communicating (to detect other Modbus Masters).
- Log Frequencies for LoRaWAN.
1.0.2
Added
- Wait cycles for optional capacitors to load and stabilize on startup
1.0.1
Changed
- Using FRAM for storing results before uploading, allowing for multiple kB of data to be sent (size depending on hardware).
Fixed
- Removed memory corruption error that could be triggered by configurations with lots of Modbus commands.
1.0.0
Added
- LoRaWAN 1.1 support
- Remote configuration via LoRaWAN on port 128.
- Clock synchronisation via LoRaWAN.
Changed
- Random delay before Uplink (to prevent persistent collisions when using multiple devices).
- Modbus responses longer than payload now get split up (additional parts on port 5).
0.4.1
Fixed
- Changed error indication bit on error 11 from
0xf0
to0x80
. - Fixed issue when parsing multiple Modbus commands from config.
0.4.0
Added
- Writing values to holding registers and coils.
- Execution of arbitrary Modbus commands triggered by LoRaWAN Downlink messages.
- Support for LoRaWAN Operation Mode Class C (for short reaction time to Downlinks).
- Automated register writing and broadcasts possible through new configuration.
Changed
- Automated reading (triggered by cron) is now configured by entering actual Modbus commands (more flexibility and usage of already existing Modbus syntax – this breaks old configurations).
- Upload format changed to sending raw response to Modbus commands (this breaks existing integrations).
Fixed
- Flushing to avoid invalid byte received from switching from TX to RX.
- Modbus mode ASCII now counts received bytes correctly.
- DataLength of 7 bits can now correctly be set in config again.
0.3.1 - 2019-05-24
Fixed
- Increased robustness of data reception on higher Baud rates.
0.3.0 - 2019-05-15
Added
- Initial release of Firmware for new Hardware revision (with RS485-addon).
- Update Modbus to support all 4 types of registers.
Changed
- Parity bit must not be subtracted from Data bits anymore.
8E1
can now be configured with8 Data bits, EVEN parity, 1 Stop bit
.
0.1.0 – 2018-08-13
Added
- Original hardware release (with RS-485 on holding PCB).
Table of Contents |
---|