Versions Compared
compared with
Key
- This line was added.
- This line was removed.
- Formatting was changed.
Downloads:
Note | ||
---|---|---|
| ||
When upgrading from Versions <0.4.1 to 0.4.1 or higher: Due to changes in the generation of the LoRaWAN parameters the default values for |
only for Round Opto-Head |
[current release] |
Head (square) |
Tip | ||
---|---|---|
| ||
We normally send e-mail notifications upon release of new firmware versions. To receive this mails you can sign up to the Lobaro newsletter here. Subscribe to our email newsletter here Make sure to select the "Firmware Updates" checkbox! |
Changelog
Firmware: app-edl21-opto
v0.4.1 [current release]
- Fixed remote append
- WARNING: Due to changes in the generation of the LoRa paramters the values for JoinEUI and AppKey will change if you use the
Restore Default
function in the Lobaro Maintenance Tool in order to reset the configuration.
v0.4.0
- Added remote config via downlink
v0.3.2
- Added initial readout before OTAA join to check optical connection
v0.3.1
- Initial release for new round Opto-Head
Legacy Downloads:
app-edl21-opto-0.3.2+LoRa.hex New Opto-Head Version (round)
app-edl21-opto-0.3.1+LoRa.hex New Opto-Head Version (round)
Markdown |
---|
# Changelog
`app-edl21-opto` – LoRaWAN with Opto Adapter for EDL21 devices.
This changelog's format is based on [Keep a Changelog](https://keepachangelog.com/en/1.0.0/),
and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0.html).
## 0.5.2 - 2021-12-23
- Optimized buffer usage
- Fixed a bug where the red led might stay on in sleep mode
## 0.5.1 - 2021-02-16
- Fixed a crash on unexpected input
## 0.5.0 - 2020-10-30
- Unified output of power on self test.
- Add support for up to 25 Obis codes (less with values of more then 8 bytes).
- Adjust data message size (on port 3) to current SF (use up to 222 bytes).
- Send multiple data message uplinks (port 3).
- Enable LostReboot feature by default
- Add new config parameter `PayloadFormat`
- Add new PayloadFormat `2` on Port `4` that prefixes data uploads with timestamp of readout
## 0.4.2 - 2020-10-07
- Built with LoRaWAN-Stack we certified in different Hardware (fixes some edge case issues).
- Redesign Changelog
## 0.4.1
- fixed remote append
- fixed reset to default issue
- WARNING: Due to changes in the generation of the LoRa parameters the values for JoinEUI and
AppKey will change if you use the Restore Default function in the Lobaro Maintenance Tool in
order to reset the configuration.
## 0.4.0
- added remote config
## 0.3.2
- added initial read before otaa
## 0.2.0
- Fix bug where readout failed after wakeup from deep sleep
- Fix bug where Obis code lookup failed |
Table of Contents |
---|