Make sure to select the"Firmware Updates"checkbox!
Starting with Firmware 0.5.0, the default values for JoinEUI (aka AppEUI), AppKey, and NwkKey in the configuration have changed. Be sure to check your LoRaWAN-Configuration between device and Network Server, after you update to this version.
You can adjust those values to your need with our config adapter.
Changelog
0.5.1 - 2020-10-15
Changed
Set standard value for config parameterLostRebootto 1 (from 0).
0.5.0 - 2020-08-12
Added
Power-On Selftest
Changed
BREAKING CHANGE: Default values for JoinEUI, AppKey, NwkKey changed!
Uses LoRaWAN-Stack that was certified for wMBus-Bridge
Implement changes in LoRaWAN-Stack that happend during certification. Implements some edge-case.
Make remote config feature robuster, e.g. when sending downlinks with ACK request.
Fixed
Fixed Mixup of Sensors that could trigger endless loop
0.4.1 - 2020-07-21
Fixed
Fix payload of sensor data
0.4.0 - 2020-06-30
Changed
Use lobawan stack v1.2.2
Sensors fromSensorIdOrderthat are missing will still be uploaded (with -0x8000 value)
WhenSendSensorId==falseuploads are done on port 3 (was port 2),
Enable 3.3V step-up only if voltage is below 3.1V (was: if below 3.3V).
Support up to 32 sensors (only 25 supported inSensorIdOrder).
0.3.3 - 2019-08-01
Added ADR config parameter
0.3.2 - 2019-08-01
Fixed Onewire init after DeepSleep
0.3.1 - 2019-07-29
Temp sensors will be printed and sent sorted by parameter "SensorIdOrder" and by ID or just by ID if parameter "SensorIdOrder" is empty
0.2.0 - 2019-02-15
Add parameter "SendSensorId" to allow skipping sensor IDs in payload
0.0.3
Bugfixes in LoraWAN stack
LoRaWAN Support for RX1 DataRate Offset
0.0.2
Don't send sensor type with ID (support 6 sensors in 50 bytes)
Add TestMode config value
Add SendInternalTemp config value
Internal sensor is send first if SendInternalTemp = true