EDL21 Electricity meter LoRaWAN Bridge
The EDL21 over LoRaWAN bridge is a device that can be used to readout modern utility meters with standardized infrared "INFO" interface.
These type of meters are called in Germany to be "EDL21"-compatible - hence the name. The meter outputs over its infrared "INFO" interface a serial protocol conforming to the Smart Meter Language Protocol 1.04 (SML). This interface is intended to be used by end-users and not for billing purposes of the electricity supplier. The read information normally contains the current consumption values of the meter and gets interpreted and forwarded by the EDL21 bridge via a LoRaWAN network to web based applications interested in further processing this data.
Warning
Older meters with "infrared pulse" output are not compatible to the Lobaro EDL21 bridge. Please check our list of compatible meters to make sure it is equipped with the correct interface.
Consider using the latest firmware on your hardware
Top Features
LoRaWAN 1.0.x and 1.1 network servers supported
LoRaWAN time synchronisation
Configuration via USB or remotely via LoRaWAN downlink
Compatible with many electrical utility meters
Configure up to 25 Obis Codes to be read
RGB Status LED
Variant with external power-supply available on request
Separation of infrared readout head and LoRaWAN antenna possible
Compatible utility meters
Electricity meter | Manufacturer | More information |
---|---|---|
DTZ541-ZEBA | Holley | External Link |
LK13 series | Logarex | External Link |
OpenWay® 3.HZ | iTron | External Link |
SGM-C4 series | efr | External Link |
SGM-D series | efr | External Link |
eHZ-K series | EMH | External Link |
mMe4.0 series | EMH | External Link |
ED300 series | EMH | External Link |
eBZD series | EMH | External Link |
ITZ series | EMH | External Link |
E320 | Landis+Gyr | External Link |
Alternative IEC 62056-21 protocol
On request we offer also the integration of electricity meters using the D0 interface conforming to IEC 62056-21. This interface is not compatible to the SML protocol. Please contact us if you need an offer for a custom firmware supporting your meter of interest.
Product variants
EDL21-LoRaWAN Bridge (universal head, XH battery connector, int. Ant.), Order number: 8000091
Customization Options
The product variant shown above is the standard variant for use with a ER34614 3.6V D-cell Battery connected over a XH connector.
Other power supply options & housing are available on request
- External antenna
- External power-supply
- NB-IoT instead of LoRaWAN
- Different infrared data formats other than SML
Contact us via support@lobaro.de if you need our offer for a special variant.
Quickstart
- Connect to the device with the Lobaro Tool using the Lobaro Config Adapter
- Under Configuration click "Reload Config" and change the fields ReadCron and ObisCode as you need followed by clicking on "Write to Device", here you can see a configuration example.
- Register the device in your LoRaWAN network
- Connect ER34614 3.6V D-cell Battery via XH connector / Connect external powersupply
- If not connected to anything the red LED will start blinking as long as no data is received, after 1 minute it will sleep for 15 seconds after every 5 retries
- Tighten the screws and install the bridge beside your electric meter
- Place the EDL21 opto head on the "Info" interface
- As soon as the EDL21 receives data its green LED will light up for 5 seconds, when connected to a LoRa Network its blue LED will light up for 5 seconds
- Check the sent data (port 3), if payload is zero the EDL21 was not able to read data, recheck proper alignment
Configuration
The configuration is done using Lobaro Maintenance Tool and the Lobaro USB PC adapter.
LoRaWAN
The connection to the LoRaWAN network is defined by multiple configuration parameters. This need to be set according to your LoRaWAN network and the way your device is supposed to be attached to it, or the device will not be able to send any data.
For a detailed introduction into how this values need to be configured, please refer to the chapter LoRaWAN configuration in our LoRaWAN background article.
Name | Description | Type | Values |
---|---|---|---|
OTAA | Activation: OTAA or ABP | bool | true = use OTAA, false = use ABP |
DevEUI | DevEUI used to identify the Device | byte[8] | e.g. 0123456789abcdef |
JoinEUI | Used for OTAA (called AppEUI in v1.0) | byte[8] | e.g. 0123456789abcdef |
AppKey | Key used for OTAA (v1.0 and v1.1) | byte[16] | |
NwkKey | Key used for OTAA (v1.1 only) | byte[16] | |
SF | Initial / maximum Spreading Factor | int | 7 - 12 |
ADR | Use Adaptive Data Rate | bool | true = use ADR, false = don't |
TimeSync | Days after which to sync time | int | days, 0 =don't sync time |
RndDelay | Random delay before sending | int | max seconds |
RemoteConf | Not supported by this firmware | bool | false =deactivate |
LostReboot | Days without downlink before reboot (triggers downlinks) | int | days, 0 =don't reboot |
Operation
Configuration values defining the behaviour of the device.
name | description | example value |
---|---|---|
ReadCron | Cron expression defining when to read | 0 0/15 * * * * for every 15 minutes |
ObisCode | Comma separated list of ObisCodes to select a subset of the available information | 1-0:1.7.255*255 = Leistung (Momentan) |
PayloadFormat | Format used for data upload (include timestamps or not) | 1 =no timestamp, 2 =include timestamp |
See also our Introduction to Cron expressions and our Introduction to Obis Codes.
LED blinking patterns
The following pattery are explained in the order in which they appear after initial power on / reset of the device.
color | duration | description |
---|---|---|
red/green/blue | 300ms each | initial pattern after reset |
red/green | 1s | NEW in 0.3.2: single readout success/failure before OTAA join |
red | short, blinking | trying to receive meter optical data for the first time after OTAA join |
green | 5 seconds | successfully received meter optical data |
blue | 5 seconds | LoRaWAN network join |
blue | short | sending LoRaWAN data uplink |
off | - | low-power mode until next sendout cycle |
As you can see by this the device will start the LoRaWAN join only after receiving optical data at least once.
Appendices
Technical characteristics
Product | |
Type name | LOB-S-EDL21-LW |
Description | Electricity meter over LoRaWAN Bridge |
RF tranceiver | |
Type | Semtech SX1272 |
Frequency | 863 MHz to 870 MHz |
Max. TX Power | max. +14 dBm |
Typical RF Range | ≤2km |
Ideal RF Range | ≤10km (free line of sight) |
LoRa communication | |
Protocol | Class A LoRaWAN 1.0.1 EU868 |
Activation method | Over-the-air-activation (OTAA) Activation by personalization (ABP) |
Encryption | AES128 |
Environmental Requirements | |
Operating temperature | -20°C – 55°C |
Max installation height | 2m |
Standards | |
Disposal / WEEE / Entsorgung
Information about the disposal of the Device.
Payload Format Status Packet (Port 1)
Once per day a status packet will be sent. It contains basic information about the device. The Battery Voltage is transmitted in 1/1000 V and the temperature in 1/10 °C. Both are in Big Endian byte order.
Version Major | Version Minor | Version Patch | Flags | Battery Voltage | Temperature |
---|---|---|---|---|---|
1 byte | 1 byte | 1 byte | 1 byte | 2 byte | 2byte |
unsigned | unsigned | unsigned | unsigned | unsigned | signed |
Payload Format 0 (old, Port 2, without exponent)
This payload was used by previous versions of the firmware and is not supported in the current version.
The payload consists of multiple entries, one entry per OBIS code given in the configuration. Each entry follows the following structure:
OBISCode (hex) | length of value (n) | value |
---|---|---|
6 bytes | 1 byte | n bytes, LSB first |
Example packet: 01 00 01 08 00 FE 08 FF 01 00 00 00 00 00 00 01 00 01 08 00 FE 08 FF 02 00 00 00 00 00 00
Entry 1:
OBISCode (hex) | length of value (n) | value |
---|---|---|
01 00 01 08 00 FE | 08 | FF 01 00 00 00 00 00 00 |
1-0:1.8.0*254 | 8 | 511 |
Entry 2:
OBISCode (hex) | length of value (n) | value |
---|---|---|
01 00 01 08 00 FE | 08 | FF 01 00 00 00 00 00 00 |
1-0:1.8.0*254 | 8 | 767 |
Payload Format 1 (new, Port 3, with exponent)
This Format is used, when the configuration parameter PayloadFormat
is set to 1
(which is the default value).
The payload consists of multiple entries, one entry per OBIS code given in the configuration. Each entry follows the following structure:
OBISCode (hex) | length of value (n) | value | exponent |
---|---|---|---|
6 bytes | 1 byte | n bytes, LSB first | 1 byte (signed) |
Example packet: 01 00 01 08 00 FE 08 FF 01 00 00 00 00 00 00 ff 01 00 01 08 00 FE 08 FF 02 00 00 00 00 00 00 02
Entry 1:
OBISCode (hex) | length of value (n) | value | exponent |
---|---|---|---|
01 00 01 08 00 FE | 08 | FF 01 00 00 00 00 00 00 | ff |
1-0:1.8.0*254 | 8 | 511 | -1 |
Value = 511 * 10^-1 = 51.1 |
Entry 2:
OBISCode (hex) | length of value (n) | value | exponent |
---|---|---|---|
01 00 01 08 00 FE | 08 | FF 02 00 00 00 00 00 00 | 02 |
1-0:1.8.0*254 | 8 | 767 | 2 |
Value = 767 * 10^2 = 76700 |
Multiple messages
The Bridge puts as many values in a single data message as possible (respecting the current Spreading Factor). When it cannot fit all values in a single message, it will send multiple data messages until all values are uploaded. It will never split a single value. Since every value is prefixed with the Obis code, the parser can easily assign values to Obis codes.
Reference decoder
This is a decoder written in JavaScript that can be used to parse the device's LoRaWAN messages. It can be used as is in The Things Network.
function readName(bytes, i) { return bytes.slice(i, i + 6); } function readValue(len, bytes, i) { if (len <= 0) { return []; } return bytes.slice(i, i + len); } function toHexString(byteArray) { var s = ''; byteArray.forEach(function (byte) { s += ('0' + (byte & 0xFF).toString(16)).slice(-2); }); return s; } function parse_int8(bytes, idx) { bytes = bytes.slice(idx || 0); var t = bytes[0]; if ((t & 1 << 7) > 0) { // temp is negative (16bit 2's complement) t = ((~t) & 0xff) + 1; // invert 16bits & add 1 => now positive value t = t * -1; } return t; } function parse_int16(bytes, idx) { bytes = bytes.slice(idx || 0); var t = bytes[0] << 8 | bytes[1] << 0; if ((t & 1 << 15) > 0) { // temp is negative (16bit 2's complement) t = ((~t) & 0xffff) + 1; // invert 16bits & add 1 => now positive value t = t * -1; } return t; } function parse_uint16(bytes, idx) { bytes = bytes.slice(idx || 0); var t = bytes[0] << 8 | bytes[1] << 0; return t; } function toNumber(bytes) { var res = 0; for (var i = 0, s = 0; i < bytes.length; i++) { res |= bytes[i] << s; s += 8; } return res; } function readVersion(bytes) { if (bytes.length < 3) { return null; } return "v" + bytes[0] + "." + bytes[1] + "." + bytes[2]; } function decodeStatus(bytes) { var decoded = { "version": readVersion(bytes), "flags": bytes[3], "vBat": parse_uint16(bytes, 4) / 1000, "temp": parse_int16(bytes, 6) / 10, }; return decoded; } function decodeSmlValuesV1(bytes) { var decoded = { values: [], }; if (bytes.length === 1) { // No Data! Read error? return decoded; } var pos = 0; while (pos < bytes.length) { var name = readName(bytes, pos); pos += 6; var len = bytes[pos]; pos += 1; var value = readValue(len, bytes, pos); pos += len; var val = { nameHex: toHexString(name), len: len, value: toNumber(value), valueHex: toHexString(value) }; decoded.values.push(val); } return decoded; } function decodeSmlValuesV2(bytes) { var decoded = { values: [], }; if (bytes.length === 1) { // No Data! Read error? return decoded; } var pos = 0; while (pos < bytes.length) { var name = readName(bytes, pos); pos += 6; var len = bytes[pos]; pos += 1; var value = readValue(len, bytes, pos); pos += len; var exponent = 1; var val = {}; if (len > 0) { exponent = parse_int8(bytes, pos); pos += 1; val = { nameHex: toHexString(name), len: len, value: toNumber(value) * Math.pow(10, exponent), valueHex: toHexString(value), }; } else { val = { nameHex: toHexString(name), len: len, value: toNumber(value), valueHex: toHexString(value), }; } decoded.values.push(val); } return decoded; } // Test input (Port 3): 01 00 01 08 00 FE 08 FF 01 00 00 00 00 00 00 FF function Decoder(bytes, port) { // Decode an uplink message from a buffer // (array) of bytes to an object of fields. switch (port) { case 1: return decodeStatus(bytes); case 2: return decodeSmlValuesV1(bytes); case 3: return decodeSmlValuesV2(bytes); } } // Wrapper for niota.io /* module.exports = function (payload, meta) { const port = meta.lora.fport; const buf = Buffer.from(payload, 'hex'); return Decoder(buf, port); } */
Example parser result
Test input (Port 3): 01 00 01 08 00 FE 08 FF 01 00 00 00 00 00 00 FF { "values": [ { "len": 8, "nameHex": "0100010800fe", "value": 51.1, "valueHex": "ff01000000000000" } ] }
CE Declaration of Conformity
CE Declaration of Conformity (pdf).
- No labels