Versions Compared
compared with
Key
- This line was added.
- This line was removed.
- Formatting was changed.
Tip | ||
---|---|---|
| ||
Please refer to Updating Firmware on the page about our Lobaro Maintenance Tool. |
Firmware Update Downloads
Download: | current version | |
app-nrf9160-temperature-TZ2-0.1.3-mcuboot-slot0-boot.hex | last version without NB-IoT support |
Markdown | ||
---|---|---|
| ||
# Changelog `app-nrf9160-temperature` This changelog's format is based on [Keep a Changelog](https://keepachangelog.com/en/1.0.0/), and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0.html). ## 0.2.1 - 2022-03-22 ### Changed - order of config parameters ## 0.2.0 - 2022-03-22 ### Added - nbiot upload - reboot on lost LoRaWAN connection ## 0.1.3 - 2022-02-18 ### Fixed - Increase power on delay after sleep, so sensors have enough time to convert temperature. ## 0.1.2 - 2202-01-31 ### Fixed - Fix reading of testing firmware name (fixes self test `factory`). ## 0.1.1 - 2022-01-31 ### Changed - Revert status message to original port 1 format for backwards compatibility. - Add Power-On wait between activating sensor power and reading sensor data. ## 0.1.0 - 2022-01-28 ### Added - New firmware created from `app-lorawan-onewire-bridge` and `app-nrf9160-onewire-bridge`. - LoRaWAN upload only (so far). - Add RemoteConfiguration, TimeSync, and LostReboot feature. ### Changed - Internal Sensor is now an emulated Sensor with all zero ID that holds the temperature measured inside the nrf. Temperature resolution is down to 1°C. Changes should be compatible with LoRaWAN format used by LoRaWAN-only 1-wire bridge. - Change status message to new Lobaro Unified Status Telegram format (on port 64). |
Table of Contents |
---|
Tip | ||
---|---|---|
| ||
Please refer to Updating Firmware on the page about our Lobaro Maintenance Tool. |
Firmware Update Downloads
Download: | app-nrf9160-temperature-TZ2-0.1.3-mcuboot-slot0-boot.hex | current version |
Markdown | ||
---|---|---|
| ||
# Changelog `app-nrf9160-temperature` This changelog's format is based on [Keep a Changelog](https://keepachangelog.com/en/1.0.0/), and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0.html). ## 0.1.3 - 2022-02-18 ### Fixed - Increase power on delay after sleep, so sensors have enough time to convert temperature. ## 0.1.2 - 2202-01-31 ### Fixed - Fix reading of testing firmware name (fixes self test `factory`). ## 0.1.1 - 2022-01-31 ### Changed - Revert status message to original port 1 format for backwards compatibility. - Add Power-On wait between activating sensor power and reading sensor data. ## 0.1.0 - 2022-01-28 ### Added - New firmware created from `app-lorawan-onewire-bridge` and `app-nrf9160-onewire-bridge`. - LoRaWAN upload only (so far). - Add RemoteConfiguration, TimeSync, and LostReboot feature. ### Changed - Internal Sensor is now an emulated Sensor with all zero ID that holds the temperature measured inside the nrf. Temperature resolution is down to 1°C. Changes should be compatible with LoRaWAN format used by LoRaWAN-only 1-wire bridge. - Change status message to new Lobaro Unified Status Telegram format (on port 64). |
Table of Contents |
---|